R_www.technology.org 2015 00003205.txt

#Promising new X-ray microscope poses technical challenges You may think the aisles in your neighborhood convenience store are crowded, but they look positively spacious compared to the passageways in the NIF target bay. The target bay bristles with dozens of instruments needed for NIF experiments, ranging from inserters that hold NIF targets in place to cameras and other diagnostics that record the results of NIF shots. Fitting a new diagnostic into the available space is always tricky, but squeezing a three-meter-long X-ray microscope into the space between the end of the diagnostic insertion manipulator (DIM) and the inner wall of the Target Bay has created unique design, logistic and engineering challenges. The new Kirkpatrick-Baez Optic (KBO) diagnostic is needed to obtain high-resolution images of the ot spotsat the center of target capsules during NIF inertial confinement fusion (ICF) implosions, explained LLNL physicist Louisa Pickworth, the project lead scientist. n the ICF experiments that wee doing, the hot spot is normally about 60 microns (millionths of a meter) across, and our current detectors have resolutions of about 10 microns or so at best, Pickworth said. e really need better than that to see what going on inside the hot spot. This microscope is going to provide much better resolution by using X-ray optics, a totally different method of imaging the implosion. And wee going to high magnifications, which is had why it to be so long. e have to get the KBO into the facility and physically fit it behind the back of the DIM and the (Target Bay) wall, said system manager Jay Ayers. o get the magnification we need (more than 10. 5x) we needed an additional one meter of space, which grossly exceeded the allowable footprint. So we had to design a one-meter telescoping section there was no other choice. The specially designed diagnostic will provide improved spatial resolution higher imaging throughput (signal strength) and the ability for wavelength selection that is currently unavailable using standard pinhole framing camera technology, Ayers said. To achieve those goals, four pairs of mirrors that make up four X-ray imaging channels must be aligned precisely. In addition, the overlapping image axis of the four pairs must be aligned to within a 50-micron radius of the center of the NIF target, and the positioning must be highly repeatable between experiments. Development of the KBO diagnostic was a collaboration between NIF & Photon Science and LLNL Physical and Life sciences (PLS) Directorate. lot of unique engineering efforts were put into this, Ayers said. he positional tolerance of the X-ray optics is very high, so we relied on two precision engineers at PLS, Todd Decker and Randy Hill, to do the design for what we call the quads. There are four channels, each comprised of X-ray optics that are pitched to one another and that also have to be pointed very accurately toward the target. hat was probably one of the most challenging aspects, he said. andy Hill deserves special credit for his creative design solutions for the precision flexures, gimbal and translation stage needed to position the optics. Kirkpatrick-Baez optics two curved razing incidencemirrors positioned at right angles to form a two-dimensional X-ray image is used a widely technology. hey work very nicely, said Tommaso Pardini of the PLS X-ray Optics Group. he interesting thing about this project is incorporated that we this vintage technology into a very difficult environment, which is NIF. ou can get in there and tweak the position of these optics after you put them in the target chamber, Pardini said. verything has to be aligned perfectly within very tight tolerances when you put it in you don have any access to it after that. That was the thing that ended up driving all the fancy engineering that Jay and Todd and Randy had to do to make sure that it actually works. When extended the telescoping snout locates the KBO mirrors at the end of a Diagnostic Load Package (DLP), cantilevered more than three meters out from its bolted connection points. e can extend (the snout) off-line, do our metrology and make sure that everything on axis, and then we can collapse it and transport it, install it and then re-extend it in the DIM, Ayers said. Another challenge was protecting the sensitive optics in the KBO diagnostic, which will be only five inches away from the extremely high-impulse target implosion shock wave during an ICF implosion. The team developed special exterior shielding and a replaceable debris window that can be exchanged easily between shots. Like the KBO itself the design of the debris window was bounded by multiple constraints: the necessary clearance from laser beampaths, the high velocity of the debris ind, and the limited access for exchange once it is loaded in the DIM. To provide wavelength filtering to accommodate different experimental needs, the team developed special multilayer coatings for the KBO system mirrors. ne thing that Livermore does very well is coating X-ray optics with these multilayers, Pardini said. hris Walton, Paul Mirkarimi, Jennifer Alameda and Regina Soufli spent quite a bit of time developing coating that would fit the requirements. Experimental flexibility will be provided by swapping mirror packs with different energy responses. Extensive simulations and off-line testing of the system optics and other components have produced good results showing substantial improvements in throughput and resolution over pinhole imaging systems. The first phase of the project, labeled KBO 1, is due to be deployed in Mid-june. KBO 2, which will feature a broadband mirror pack, is scheduled for fall of this year; and KBO 3, designed for hardened X-ray cameras for use in high-neutron-yield experiments, is due to be deployed in fiscal year 2016. ee integrating a lot of new and different ways of doing things into this diagnostic, Pickworth said. hat wee going to produce at the end of the day is going to be much better than the imaging systems that we currently have limited, with detector resolution and a lot more throughput than other imaging systems. n


< Back - Next >


Overtext Web Module V3.0 Alpha
Copyright Semantic-Knowledge, 1994-2011