www.biosciencetechnology.com 2015 01127.txt.txt

#Building a Better Microscope to See at the Atomic Level One of the more famous images in biology is known as"Photo 51, "an image of DNA that chemist Rosalind Franklin and Raymond Gosling created in 1952 by shooting X-rays through fibers of DNA and analyzing the patterns they left behind on film. One of the more famous images in biology is known as"Photo 51, "an image of DNA that chemist Rosalind Franklin and Raymond Gosling created in 1952 by shooting X-rays through fibers of DNA and analyzing the patterns they left behind on film. That image provided Nobel prize winners James Watson and Francis Crick with crucial information they needed to determine the 3d structure of DNA knowledge that ultimately gave rise to molecular biology. For much of the 20th century, this method of analyzing X-ray diffraction patterns has been the standard for determining the 3d structures of proteins, generally using a technique known as X-ray crystallography. But this method relies on getting proteins to pack tightly together to form uniform crystals, which is notoriously difficult, especially when it comes to the floppy, dynamic proteins that live in cell membranes. Yet biologists are interested particularly in these membrane proteins because the membrane is the cell dock, its security checkpoint, its mailbox. From sugars to viral invaders to nerve impulses all cellular traffic passes through the cell membrane, and likely interacts with the proteins embedded there, such as neurotransmitter and hormone receptors. To understand all that transpires at the membrane, biologists need to zoom in to the atomic level. The proteinsresistance to crystallization, therefore, left scientists in a bind. Now, after decades of challenges, scientists have developed an imaging technique that allows them to visualize these tiny membrane proteins thousands of times smaller than the width of a human hair and to do so without first having to form crystals. Revisualizing a Classic Technique Known as single-particle cryo-electron microscopy or CRYO EM, the technique had largely been written off as useless for determining the structure of very small proteins. But technological refinements made over the past several years at UC San francisco and other institutions have made CRYO EM a key tool in structural biology. ryo-EM has made this marked jump in the last three or four years in terms of resolution, so that we can go from just seeing the general outline of a protein, what people used to refer to as lob-ology, and now see, actually, the atomic structure, said David Julius, Ph d.,professor and chair of UCSF Department of Physiology. Julius collaborated with Yifan Cheng, Ph d.,associate professor of biochemistry and biophysics, to use CRYO EM to visualize the structure of the body receptors that sense the spiciness of chili peppers and, in work reported last month, wasabi. These receptors are involved also in how the body signals pain and the findings are already being used to test new pain drugs that bind to these receptors. y being able to really determine a molecule atomic structure, you can understand how it works in detail, you can make connections between the biology and chemistry, and it also provides capability for drug discovery and design, said David Agard, Ph d.,professor of biophysics and biochemistry and a Howard hughes medical institute (HHMI) investigator, who worked with Cheng to create better cameras and software for CRYO EM. o it really a huge change in what possible. etter Camera, Better Picture Yet for a long time, scientists didn believe electron microscopy would be useful for imaging proteins and other biological samples at all. The problem was that electron microscopes work by shooting electrons at the speed of light through a biological sample suspended in a vacuum; this process often destroyed the raw biological samples researchers were trying to see. Then in the 1970s and 1980s, researchers at Heidelberg European Molecular biology Laboratory and Lawrence Berkeley National Laboratory developed a way to protect samples and also keep them in a dissolved state similar to how they live in the cell: they rapidly freeze the purified biological samples in a very thin layer of liquid. Yet even when frozen at around-300°F, the tiny proteins still moved when hit by the powerful stream of electrons. So scientists turned to using very low electron doses analogous to taking a photo in very low light which minimizes the damage but leaves the image grainy. To reduce this blur, the team developed a new camera that records a movie of the wiggling sample under the microscope. At 400 frames per second, the recording provides enough data so the motion correction software developed in Cheng laboratory can correct for the molecular motion and effectively nblurthe image. Another challenge was that earlier digital cameras used in CRYO EM detected light not electrons. So when the electron passed through the sample the signal had to be translated into light signals, and resolution was lost in the process. his combination of the bad detector, blurring from the motion and radiation damage, where the sample was being destroyed by the electrons, made it all a very difficult process, said Agard. To circumvent the problem of translating electrons into light, Cheng and Agard brought together a team and developed a camera that detects electrons directly. The researchers collaborated with the electron microscopy company Gatan and scientists at Lawrence Berkeley to build a new detector called the K2 Summit, named after one of the most challenging mountain ascents in the world. The World at Near-Atomic Resolution In 2013, Cheng and Julius reported that they had used this new camera to achieve near-atomic-level structure of the capsaicin receptor, TRPV1, which detects the heat of chili peppers. CRYO EM had previously been used to examine larger structures, like ribosomes and viruses, but this was the first membrane protein to which the technique had been applied. small thing like a TRP channel, that was a real revelation, said Nikolaus Grigorieff, who does CRYO EM research at HHMI Janelia Research Campus, In virginia. Earlier this year, Cheng and Julius determined the structure of another key protein receptor, TRPA1, involved in how the body signals pain. There will be many revelations to come. he future very exciting, for sure, said Cheng. his opens up tremendous opportunities for the field to tackle many challenging problems in structural biology. The resolution of CRYO EM as used by Cheng and Agard is currently about 3 ångströms; for reference, an ångström is about one-millionth the width of a strand of hair. Cheng and Agard would like to take it down to 2 ångströms, which would allow them to see not just membrane proteins but also the way that molecules, such as new therapeutics, might bind to them. Cheng plans to use CRYO EM to examine the same molecule that Watson, Crick, and Franklin probed over 60 years ago DNA and, more specifically, chromatin, the term for DNA in complex with its associated proteins.""These are extremely difficult targets for X-ray crystallography, and I anticipate that CRYO EM will also play a significant role in this area.""Source: University of California San Francisc r


< Back - Next >


Overtext Web Module V3.0 Alpha
Copyright Semantic-Knowledge, 1994-2011